mirror of
https://github.com/iDescriptor/iDescriptor.git
synced 2026-06-21 19:35:49 +08:00
fix windows build
This commit is contained in:
@@ -73,13 +73,16 @@ jobs:
|
||||
$env:PATH = "$wixToolDir;$env:PATH"
|
||||
"PATH=$wixToolDir;$env:PATH" | Out-File -FilePath $env:GITHUB_ENV -Append
|
||||
|
||||
# Install the UI extension (user-level)
|
||||
wix extension add WixToolset.UI.wixext/4.0.5
|
||||
wix extension list
|
||||
# Install the UI extension
|
||||
& "$wixToolDir\wix.exe" extension add WixToolset.UI.wixext/4.0.5
|
||||
& "$wixToolDir\wix.exe" extension list
|
||||
|
||||
# Set environment vars for CPack
|
||||
"WIX=$(Join-Path $wixToolDir 'wix.exe')" | Out-File -FilePath $env:GITHUB_ENV -Append
|
||||
"WIX_EXTENSIONS=$env:USERPROFILE\.wix\extensions" | Out-File -FilePath $env:GITHUB_ENV -Append
|
||||
|
||||
# Set the extensions path for CMake/CPack
|
||||
$extensionsPath = Join-Path $env:USERPROFILE ".wix\extensions"
|
||||
"CPACK_WIX_EXTENSIONS=$extensionsPath" | Out-File -FilePath $env:GITHUB_ENV -Append
|
||||
|
||||
- name: Set PKG_CONFIG environment variable
|
||||
run: echo "PKG_CONFIG_EXECUTABLE=C:/msys64/mingw64/bin/pkg-config.exe" >> $GITHUB_ENV
|
||||
|
||||
+12
-1
@@ -3,6 +3,7 @@ project(iDescriptor VERSION 0.1.0 LANGUAGES CXX)
|
||||
|
||||
# Feature options
|
||||
option(ENABLE_RECOVERY_DEVICE_SUPPORT "Enable recovery device support (requires libirecovery)" ON)
|
||||
set(PACKAGE_MANAGER_HINT "" CACHE STRING "Name of package manager(s) used to manage this build (e.g. paru, yay, pamac)")
|
||||
option(PACKAGE_MANAGER_MANAGED "Build as package manager managed version (auto updates will be handled by the package manager)" OFF)
|
||||
|
||||
set(CMAKE_AUTOUIC ON)
|
||||
@@ -327,10 +328,14 @@ if(ENABLE_RECOVERY_DEVICE_SUPPORT)
|
||||
target_compile_definitions(iDescriptor PRIVATE ENABLE_RECOVERY_DEVICE_SUPPORT)
|
||||
endif()
|
||||
|
||||
if (PACKAGE_MANAGER_MANAGED)
|
||||
if(PACKAGE_MANAGER_MANAGED)
|
||||
target_compile_definitions(iDescriptor PRIVATE PACKAGE_MANAGER_MANAGED)
|
||||
message(STATUS "Building as package manager managed version, updates will be handled by the package manager")
|
||||
endif()
|
||||
if(PACKAGE_MANAGER_HINT)
|
||||
message(STATUS "Configured package manager hint: ${PACKAGE_MANAGER_HINT}")
|
||||
target_compile_definitions(iDescriptor PRIVATE PACKAGE_MANAGER_HINT=\"${PACKAGE_MANAGER_HINT}\")
|
||||
endif()
|
||||
|
||||
target_compile_definitions(iDescriptor PRIVATE
|
||||
APP_VERSION="${PROJECT_VERSION}"
|
||||
@@ -443,6 +448,12 @@ if(WIN32)
|
||||
string(UUID CPACK_WIX_PRODUCT_GUID NAMESPACE "1a2b3c4d-5e6f-7a8b-9c0d-1e2f3a4b5c6d" NAME "${PROJECT_NAME}" TYPE MD5)
|
||||
string(UUID CPACK_WIX_UPGRADE_GUID NAMESPACE "d6c5b4a3-f2e1-d0c9-b8a7-f6e5d4c3b2a1" NAME "${PROJECT_NAME}" TYPE MD5)
|
||||
set(CPACK_WIX_UI_REF "WixUI_InstallDir")
|
||||
|
||||
# Explicitly set the WiX extensions path
|
||||
if(DEFINED ENV{USERPROFILE})
|
||||
set(CPACK_WIX_EXTENSIONS "$ENV{USERPROFILE}/.wix/extensions")
|
||||
endif()
|
||||
|
||||
set(CPACK_WIX_INSTALL_SCOPE "perMachine")
|
||||
set(CPACK_WIX_PROGRAM_MENU_FOLDER "${PROJECT_NAME}")
|
||||
set(CPACK_PACKAGE_EXECUTABLES "iDescriptor" "iDescriptor")
|
||||
|
||||
Reference in New Issue
Block a user